Metos Viking Combi 4G Kettle Installation and Operation Manual

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-featured

Metos-logo

Metos Viking Combi 4G Kettle Installation

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-product

General – Metos

Carefully read the instructions in this manual as they contain important information regarding proper, efficient, and safe installation, use, and maintenance of the appliance. Keep this manual in a safe place for eventual use by other operators of the appliance.

The installation of this appliance must be carried out according to the manufacturer’s instructions and following local regulations. The connection of the appliance to the electric, steam, and water supply must be carried out by qualified persons only.

Persons using this appliance should be specifically trained in its operation. Switch off the appliance in the case of failure or malfunction. The periodic function checks requested in the manual must be carried out according to the instructions.

Have the appliance serviced by a technically qualified person authorized by the manufacturer and using original spare parts. Not complying with the above may put the safety of the appliance in danger.

Symbols used in the manual

  • This symbol informs about a situation where a safety risk might be at hand. Given instructions are mandatory to prevent injury.
  • This symbol informs about the right way to perform to prevent bad results, appliance damage, or hazardous situations.
  • This symbol informs about recommendations and hints that help to get the best performance out of the appliance.

Safety

The appliance is CE-marked, which means that it complies with the requirements of the EU machinery directive about product safety. Product safety means that the design of the appliance will prevent personal injury or damage to property.

The Viking kettle has been designed and manufactured in compliance with the Directive regarding the safety of Machinery, the Low Voltage Directive, the Directive regarding Electromagnetic Compatibility, and the Directive regarding Pressure Equipment currently in force.

  • Changing the settings and adjustments
    Technical adjustments to the appliance must be performed by a qualified and well-trained person.
  • Safety instructions in the event of malfunction
    In case of a serious emergency, all functions of the appliance must be stopped by turning the main switch to the OFF position.
  • Disposal of the appliance
    Once the appliance has reached the end of its useful life, it must be disposed of in compliance with local rules and regulations.
  • Other prohibitions (dangerous methods and procedures)
    Deliberate disregard of safety devices is prohibited, as it jeopardizes safe work in the kitchen. The manufacturer does not take responsibility for damage caused by the deliberate use of a defective appliance, disregard the safety precautions by modifying the designed operation of the appliance, or neglect the technical condition, maintenance, or service of the appliance.

Warnings

Please take careful note of the following instructions and warnings. Further on in this manual, some warnings are to be noted in special operation situations. To prevent damage and accidents, please read the whole manual before attempting to operate the appliance.

  • Viking kettles are to be used only for food preparation. Interacting or corrosive substances are not to be prepared in the kettle.
    Note that also long-term effect of some food preparation substances, such as salt, acetic acid, lemon acid, and lactic acid, can be corrosive.
  • To prevent burns, do not touch the inner surface and the rim of the kettle, safety lid, and mixing tool. Do not put your hands, without appropriate protection, above the kettle while cooking.
  • Beware of hot steam when removing the lid.
  • Do not open the control valve of the steam generator, the safety valve, or the water inlet valve when there is pressure in the steam jacket. Releasing hot steam might cause burns.
  • Do not stand behind the kettle during tilting.

Functional description

Intended use of the appliance

The kettle is designed for professional food preparation. Using the kettle for other purposes is prohibited. It is forbidden to put corrosive ingredients or substances reacting with each other in the kettle. Please observe that the long-term effect of some food preparation substances is corrosive. Such substances are, for example, salt, acetic acid, citric acid, and lactic acid.

Construction of the kettle

The main parts of the kettle / combi-kettle are illustrated in the following pictures:

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-1

  1. Support pillar
  2. Safety block
  3. Mixer and mixing tool (only for Viking Combi)
  4. Emptying valve for steam generator/steam jacket
  5. Safety lid
  6. Safety grid for fill opening
  7. One-grip tap for hand shower
  8. Control panel
  9. Emergency/stop button
  10. Handshower
  11. Water fill to kettle
  12. The free-standing frame (option)

Lid

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-2

  1. Safety lid
  2. Lifting arm
  3. The locking lever of the lid
  4. Safety grid for fill opening
  5. Safety switch
  6. Cover for fi ll opening (not shown in picture)

Mains switch

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-3

  1. Mains switch

Control panel

The control panel and the available functions on the kettle are different depending on what options are available. This manual covers all options. The functions and controls depend on selected features: The functions of the different versions are:

Viking Basic

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-4

  • Power regulator
  • Heating on indicator
  • Manual water filling
  • Kettle bowl tilting
  • Return the kettle bowl to an upright position
  • ”Low water level” indicator (electrically heated models) ”Steam supply open” indicator (steam heated models)
  • Emergency/stop button

Viking Combi with cooling and water automatics

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-5

  1. Power regulator
  2. Heating on indicator
  3. Cooling
  4. Mixing speed regulator
  5. ”Mixer ON” indicator
  6. Automatic water filling
  7. Kettle bowl tilting
  8. Return the kettle bowl to an upright position
  9. Mixing program selector switch
  10. Food temperature display
  11. ”Low water level” indicator (electrically heated models) ”Steam supply open” indicator (steam heated models)
  12. Emergency/stop button

Operating instructions

All personnel using the appliance must be given training in how the appliance works by the person responsible for staff safety.

Cooking

The temperature of the steam jacket of the kettle is always at least the same as the room temperature or the same as the temperature of the cooling agent if the kettle is equipped with a cooling attachment (option).

Starting to cook

  • Check that the emergency/stop button is not pressed down. The emergency/stop button can be released by turning it clockwise until it jumps up.
  • Switch on the power by turning the power regulator (1) to the right (green signal lamp (2) illuminates).
    • If the white water level indicator light (3) does not go off, add water to the steam generator according to the instructions, see “Filling the steam generator (electrically heated models without cooling or auto. jacket filling).
    • The white signal lamp (3) illuminates when the steam supply is open (steam-heated models).

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-6

  1. Power regulator
  2. The indicator light “kettle ON”
  3. Indicator light for low water level (electrically heated models) Indicator light “steam supply open” (steam heated models)
  4. Emergency/stop button
  5. Food temperature display

After use

Cleaning

Use of a pressure washer is forbidden. Pressure washers generate huge amounts of water fog that might contribute to the contamination of food and food-handling surfaces over large areas in the kitchen. Switch off the appliance with the mains switch before starting to wash the kettle.

Tools not allowed for cleaning:

  • pressure washer
  • all metallic tools
  • rough rubbing sponges
  • steel wool
  • abrasive detergents

Tools recommended for cleaning:

  • special detergents for stainless steel
  • nylon brush
  • soft rubbing sponges
  • other materials intended for stainless steel that do not scratch the surface

Emptying the steam jacket (steam-heated kettles)

Open the drain valve of the steam jacket at the end of the working day so that the water that may condense in the kettle can drain into the drain. That way it won’t interfere with the next cooking event. Remember to close the drain valve the next morning before heating the kettle.

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-16

Detaching the lid parts

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-17

  • Make sure the kettle is in an upright position.
  • Place the lid on the kettle.
  • Remove the cover of the safety grid and detach the safety grid.
  • Detach the solid lid from the lifting arm by holding the lifting arm with one hand and pulling the locking lever of the lid and then lifting the arm.

Refitting the lid parts

Place the solid lid on the kettle approximately in the correct position. Pull the lifting arm down over the lid. Turn the solid lid so that the guiding pin lines up with the hole in the lifting arm centerpiece.Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-18

  1. Solid lid
  2. Lifting arm
  3. Guiding pin
  4. The locking lever of the lid
  5. Safety grid for lid opening
  6. Cover for fi ll opening (not shown in picture)

Press the lid arm against the lid so that the fi xing cone is guided into the fi xing part and the locking lever snaps in the locked position. Make sure that the lid is locked on the arm.Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-19

Put the safety grid and its cover in place.

Installation

General

Please observe the instructions given in this chapter concerning the installation and adjustments that must be done before taking the kettle into use. Strict observance of the instructions prevents malfunctions and damages potentially caused by defective installation.

Unpacking the appliance

The kettle should be transported in its package as close as possible to the installation place before final unpacking. Do not remove the protective film until after installation, just before the first use of the kettle.

Residual current device recommendation

It is recommended to use a residual current device in the installation of a kettle as follows:

  • Kettles without mixer: Type A residual current device.
  • Kettles with mixer and operating voltage 200V, 230V, or 400/230V: Type A residual current device with high-frequency filtering or a residual current device separately approved for use with frequency converters.
  • Kettles with mixer and operating voltage 380 – 480V without neutral: Type B three-phase residual current device.

Installation frames

Positioning of installation frames

Single kettle

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-7

Kettle group

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-8

Subsurface frame cast into the floor

Installation frames are mounted according to the installation drawing, with the help of installation guides supplied with the delivery. The frames must be installed in a horizontal position and fixed so that they do not move during casting. The installation frames must be positioned so that their upper surface is 172 mm above the finished floor surface.

The junction of the installation frame and floor is filled with the flooring material. To achieve the best result regarding tightness, the installation frame should be filled up to the top level with concrete mass which is covered with floor coating after the installation.

Make sure that the protective sleeves of the fixing bolts are in place before filling the installation frame. The main points concerning the installation of the subsurface frame are shown in the picture below.Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-9 Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-10

  1. Installation frame
  2. Concrete casting
  3. Finished floor surface
  4. Floor coating
  5. Fixing bolt
  6. Protecting sleeve for fi xing bolt
  7. Adjusting bolt

Place the kettle on the installation frame and adjust it to a horizontal position with the adjusting bolts. When the kettle is in a horizontal position, it must be fixed to the installation frames with the help of the fixing bolts. The control pillar has 4 bolts and the support pillar has 2 bolts. Tighten the adjusting nuts carefully. Do not seal the space between the kettle pillars and installation frame as there must be enough change of air.

Technical specifications

Dimensions

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-11 Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-12

The minimum free distance to any structure behind the kettle needed for tilting the kettle is dimension L depending on the model. However, service access to the components under the kettle bowl requires a bigger dimension M. National and local regulations must be observed when installing the combi kettle.

Floor drain and installation frame positioning

Metos Viking Combi 4G Kettle Installation and Operation Manual 20 Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-14

Steam connection

Metos-Viking-Combi-4G-Kettle-Installation-and-Operation-fig-15

Water connection

  • Cold water connection R1/2” ( ø15 ). Must be fitted with a one-way valve and shut-off valve.
  • Hot water connection R1/2” ( ø15 ). Must be fitted with a one-way valve and shut-off valve. (option)

Spare parts not covered by warranty

Wearing parts are not covered by the warranty. Wearing parts include:

  • Scrapers of the mixing tool
  • Brush part of the washing tool
  • Other similar parts

Metos Oy Ab
Ahjonkaarre, FI-04220 Kerava, Finland
Tel. +358 204 3913
e-mail: metos.finland@metos.com
www.metos.com

FAQs About Metos Viking Combi 4G Kettle Installation

What is the Metos Viking Combi 4G Kettle?

The Metos Viking Combi 4G Kettle is a commercial-grade cooking appliance that combines a kettle and a tilting bratt pan. It is designed for use in professional kitchens and food service establishments.

What are the key features of the Metos Viking Combi 4G Kettle?

Some key features of the Metos Viking Combi 4G Kettle may include stainless steel construction, a gas-powered burner system, precise temperature control, and a tilting mechanism for easy pouring and cleaning.

What are the installation requirements for the Metos Viking Combi 4G Kettle?

The installation requirements for the Metos Viking Combi 4G Kettle may vary depending on local building codes and regulations. However, common requirements may include proper ventilation, gas supply connections, electrical wiring, and clearance space around the appliance.

Do I need a professional installer to install the Metos Viking Combi 4G Kettle?

While installation requirements may vary, it is recommended to hire a professional installer or technician familiar with commercial kitchen equipment to ensure proper installation and compliance with safety regulations.

Is there a user manual or installation guide available for the Metos Viking Combi 4G Kettle?

Yes, there should be a user manual or installation guide provided with the Metos Viking Combi 4G Kettle. This document typically includes detailed instructions for installation, operation, maintenance, and troubleshooting.

What safety precautions should I take during the installation of the Metos Viking Combi 4G Kettle?

When installing the Metos Viking Combi 4G Kettle, it is important to follow all safety guidelines and precautions outlined in the user manual. This may include ensuring proper ventilation, securing gas and electrical connections, and avoiding hazards such as leaks and electrical shocks.

Are there any specific requirements for the gas supply connection?

Yes, the gas supply connection for the Metos Viking Combi 4G Kettle should be installed by a qualified professional and comply with local building codes and regulations. This typically involves using approved gas piping and fittings, as well as ensuring proper ventilation and gas pressure regulation.

Where can I find technical support or assistance with the installation of the Metos Viking Combi 4G Kettle?

Technical support for the installation of the Metos Viking Combi 4G Kettle may be available through the manufacturer’s customer service department or authorized service providers. You can also refer to the user manual or installation guide for troubleshooting tips and contact information.

Can the Metos Viking Combi 4G Kettle be installed in any kitchen layout?

While the Metos Viking Combi 4G Kettle is designed to be versatile and adaptable to various kitchen layouts, it is important to consider factors such as ventilation, clearance space, and access to utilities when planning the installation. Consulting with a professional installer or kitchen designer can help ensure optimal placement and functionality.

Where can I find more information about the installation of the Metos Viking Combi 4G Kettle?

For detailed installation instructions and specifications, refer to the product manual provided by Metos or contact their customer support for assistance. Additionally, consulting with a professional installer or technician can provide valuable guidance tailored to your specific installation requirements.

For More Manuals by Metos, Visit Latest Manuals

Metos Viking Combi 4G Kettle Installation and Operation Manual 24 Metos Viking Combi 4G Kettle Installation Operation Manual [pdf]

Leave a Reply