Thank you for purchasing the Vicks No Touch Thermometer (VNT200). This thermometer is a high-quality product tested by international standards.

The product can provide a stable, accurate reading with each measurement. The thermometer performs a self-test every time it is switched on, to guarantee measurements’ accuracy.

Please read these instructions carefully before using this product and keep the instructions and thermometer safe.

Indications for Use

The Vicks VNT200 No Touch Forehead Thermometer is a non-sterile, reusable, clinical thermometer intended for the intermittent determination of human body temperature in a “no touch” mode, using the center of the forehead as the measurement site on people of all ages, in a home use environment.

Important Safety Instructions

  • Keep out of reach of children under 12 years.
  • NEVER use the thermometer for purposes other than those for which it has been intended. Please follow the general safety precautions when using on children.Ezoic
  • NEVER immerse the thermometer in water or other liquids (not waterproof). Please follow the “Care and Cleaning” instructions for cleaning.
  • DO NOT store this thermometer in temperature extremes below -25 °C or over 55 °C (below -13 °F or over 131 °F) or in excessive humidity (up to 95% non-condensing relative humidity).
  • Let the thermometer and the individual being measured acclimate to the temperature of the room in which the measurement will be taken.
  • The thermometer needs to adjust to the room temperature for 30 minutes before taking a measurement.
  • The individual being measured should be indoors for 30 minutes before taking a measurement. External temperature can impact skin temperature.
  • DO NOT use the thermometer if there are signs of damage on the scanner or on the thermometer itself. If damaged, DO NOT attempt to repair the product.
  • NEVER insert a sharp object into the scanner area or any other open surface on the thermometer.
  • This thermometer consists of high-quality precision parts. DO NOT drop
    the instrument. Protect it from severe impact and shock. DO NOT twist the instrument or the measuring sensor.
  • This thermometer is intended for household use only.Ezoic
  • Use of this thermometer is not intended as a substitute for consultation with your physician.
  • Temperature elevation may signal a serious illness, especially in neonates and infants, or in adults who are old, frail, or have a weakened immune system. Please seek professional advice immediately when there is a temperature elevation and if you are taking the temperature on:
    • Neonates and infants under 3 months (Consult your physician immediately if the temperature exceeds 37.4 °C [99.4 °F])
    • Individuals over 60 years of age (Fever may be blunted or absent in older patients)
    • Individuals having diabetes mellitus or a weakened immune system
      (e.g., HIV positive, cancer chemotherapy, chronic immunosuppressant treatment, splenectomy)
    • Bedridden Individuals (e.g., nursing home patients, stroke, chronic illness, paraplegia, quadriplegia, surgical recovery)
    • A transplant recipient (e.g., liver, heart, lung, kidney)
  • This thermometer is not intended for pre-term babies or small-for-gestational-age babies. Pre-term is defined as a baby, born before 37 weeks of pregnancy are completed. Small-for-gestational age is defined as a newborn baby (birth to 4 weeks of age), born at 37 weeks or later, with a weight below the 10th percentile for newborn babies of the same gestational age.
  • This thermometer is not intended to interpret hypothermic temperatures. If the device displays a temperature of 36.4 °C (97.5 °F) or less with an LED backlight color green or white, and the individual is exhibiting atypical symptoms or behaviors, contact your physician or health care professional.
  • DO NOT allow children to take their temperatures unattended.
  • Please consult your physician if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc., even in the absence of fever.
  • Even in the absence of a fever, those who exhibit a normal temperature may still need to receive medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.
  • DO NOT modify this equipment without the authorization of the manufacturer.

Product Description

Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-1

  1. Power Button
  2. Scanner
  3. LCD Screen
  4. Mode Button
  5. Memory Button

How does the Vicks No Touch work?

The No Touch Thermometer measures infrared energy radiated from the skin at the center of the forehead area. This captured energy is collected through the lens and converted to a body temperature value.

The No Touch Thermometer has been clinically tested and proven to be safe and accurate when used by its operating instruction manual.

Ezoic

Temperature Guidance Feature

Temperature guidance helps you to better understand the meaning of your child’s temperature with the color indicated on the display.

The screen displays GREEN for a normal temperature, YELLOW for an elevated temperature, and RED for a high temperature. 4 double beeps indicate temperatures above 37.4 °C (99.4 °F) to alert the user that the individual may have a temperature.

Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-2

Ezoic

NOTE: Backlight remains OFF when below temperature readings are registered: 34°C ≤ T ≤ 35.7 °C (93.2°F ≤ T ≤ 96.3 °F)

Temperature Taking Hints

It is important to know each individual’s normal temperature when they are well. This is the only way to accurately diagnose a fever. Take multiple readings when healthy to determine normal temperature. A child’s normal temperature can be as high as 37.7 °C (99.9 °F) or as low as 36.1 °C (97.0 °F).

Be sure to note this unit reads 0.5 °C (0.9 °F) lower than a rectal digital measurement. The individual being measured and the thermometer should be at the same ambient temperature for 30 minutes.

ALWAYS hold the thermometer and the forehead steady when taking a reading. DO NOT move the thermometer until you hear the final beep.

DO NOT measure while or immediately after nursing a baby. Individuals should not drink, eat, or be physically active before/while taking the measurement. Remove hats and wait 30 minutes before taking a measurement. Before taking a measurement, remove dirt or hair from the forehead area.

Wait 10 minutes after cleaning the forehead before taking a measurement. ALWAYS take the temperature exactly as directed. Temperature results may vary if positioned in the wrong location or wrong distance from the forehead.

How To Use The Vicks No Touch Thermometer For Human Temperature

For Human Temperature

Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-3

  1. Turn On
    Press the POWER button to turn the device on. The device will be ready to take a measurement when 4 dashes appear on the LCD screen and the °F or °C symbol is displayed in the right top corner. “Body” will also be displayed in the left top corner.Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-4
  2. Position
    Position the thermometer 0.4-2 inches (1-5 cm) away from the center of the forehead, just between the eyebrows. If the eyebrow area is covered with hair, sweat, or dirt, please clean the area beforehand to improve reading accuracy. It is important to hold the thermometer and the forehead steady during measurement. The movement will impact the temperature reading.Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-8
  3. Take Temperature
    Press the POWER button to take a temperature measurement.Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-6
  4. Read Temperature
    One long beep for normal temperature and 4 double beeps for elevated or high temperature will be heard when the measurement is complete (unless you have the sound muted). The LCD backlight will illuminate green, yellow, or red. To take another reading repeat steps 2-4.
  5. To Turn Off
    To conserve battery power, the unit will automatically shut down after 20 seconds of no use.

How To Use The Vicks No Touch For Food & Bath Temperatures

  1. Select Surface Temperature Setting
    With the device powered On, press the MODE button to switch from human to surface temperature. The screen will change from “body” to “surface temp” on the top of the LCD screen.Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-7
  2. Position
    Position the thermometer 0.4-2 inches (1-5 cm) away from food or bath water. Ensure that you are aiming directly at the food or bath water and not at the food container or walls of the bathtub. Ensure that the thermometer is not directly in line with steam, as this can impact the reading. DO NOT touch food or bath water with the thermometer.
  3. Take Temperature
    Press the POWER button to take a temperature measurement.Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-5
  4. Read Temperature
    A confirmation beep will be heard, indicating the measurement is complete. The temperature measurement will be displayed on the LCD screen.Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-9

Note: The backlight will be green regardless of temperature measurement when in food/bath mode.

How To View Temperatures In Memory

Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-10

Press the “MEMO” button to view previous temperatures. The previous 10 temperatures can be displayed on the LCD screen. The most recent temperature taken will be the first temperature displayed after pressing the “MEMO” button.

To view the next most recent temperature taken, press the “MEMO” button again. To clear the memory of previous temperatures, press and hold the “MEMO” button for 4 seconds.

Error Messages

Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-11 Vicks-VNT200-No-Touch-3-in-1-Thermometer-fig-12

Care and Cleaning

The thermometer should be cleaned between uses. Use an alcohol swab or a cotton swab moistened with alcohol (70% Isopropyl) to wipe the thermometer casing and measuring probe for 90 seconds. Wait 10 minutes, allowing the thermometer to air-dry, before taking a measurement. Ensure that no liquid enters the interior of the thermometer.

NEVER use abrasive cleaning agents, thinners, or benzene for cleaning, and NEVER immerse the thermometer in water or other cleaning liquids. NEVER insert a sharp object into the scanner area or any other open surface on the thermometer.

Warranty

You should first read all Instructions before attempting to use this product

This 1-year limited warranty applies to repair or replacement of products found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use, or supplemental damage.

Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you.

This warranty gives you specific legal rights, and you also may have other rights that vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase. B.

At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship. C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not by the instruction manual.

Call us toll-free at 1-800-477-0457 or e-mail: ConsumerRelations@HelenofTroy.com. Please be sure to specify a model number.

Product Specifications

  • Type: No Touch Thermometer (VNT200)
  • Measuring range: Body: 34.0 °C – 43.0 °C (93.2 °F – 109.4 °F)
    • Object: 0 °C – 100.0 °C (32.0 °F – 212.0 °F)
  • Resolution: 0.1 °C (0.1 °F)
  • Laboratory Accuracy:
    • Body Mode:
    • ±0.2 °C for the range 35.0 °C – 42.0 °C
    • (±0.4 °F for 95.0 °F – 107.6 °F)
    • ±0.3 °C (±0.5 °F) for the range outside
    • 35.0 °C – 42.0 °C (95.0 °F – 107.6 °F)
    • Surface Mode:
    • ±2.0 °C for the range 0.0 °C – 100.0 °C
    • (±3.6 °F for 32.0 °F – 212.0 °F
  • Display: Liquid Crystal Display, 4 digits plus special icons
  • Acoustic: Normal: Green backlight, One long beep for normal temperature
    • Elevated or high temperature: Yellow or Red backlight, 4 double beeps Erase memory: one long beep
  • Operating temperature: 15 °C – 40 °C (59.0 °F to 104 °F)
  • Automatic Switch-off: Approx. 20 seconds after any button is pressed
  • Weight: 85.6 g (with batteries), 63.0 g (w/o batteries)

This infrared thermometer meets the requirements established in ASTM Standard E 1965-98 (for the thermometer system). Full responsibility for the conformance of the product to the standard is assumed by Kaz, USA, Inc., a Helen of Troy Company, Health & Home, 400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752.

ASTM laboratory accuracy requirements for the thermometer only in the display range of 36 °C to 39°C (96.8 °F to 102.2 °F) for infrared thermometers is ±0.3 °C (±0.5 °F), whereas, for mercury-in-glass and electronic thermometers, the requirement per ASTM Standards E 667-86 and E 1112-86 is ±0.1 °C (±0.2 °F).

This device conforms to the following standards:

  • EN 60601-1:2014 – Medical Electrical Equipment – Part 1: General requirements for basic safety and essential performance
  • ISO 80601-2-56:2017 – Medical electrical equipment – Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
  • ASTM E1965-98:2016 – Standard Specification for Infrared Thermometers for Intermittent Determination of Patient TemperatureEzoic
  • IEC 60601-1-2:2014 Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral Standard: Electromagnetic disturbances – Requirement and tests
    NOTE: DO NOT use this device in the presence of electromagnetic or other interference outside the normal range specified in IEC 60601-1-2:2014.
  • ISO 15223-1:2016 – Medical devices – Symbols to be used with medical device labels, labeling and information to be supplied – Part 1: General requirements
  • EN 1041:2013 Information supplied by the manufacturer of medical devices
  • IEC 60601-1-11:2015 Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance
    • Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
  • To protect the environment, dispose of empty batteries at appropriate
    collection sites according to national or local regulations.
  • Keep out of reach of young children, the elderly, and pets.
  • BF Type applied part.
  • See Instruction of use.
  • Protected against solid foreign objects of 12.5 mm diameter and larger. Protected against water drops falling vertically when the device is tilted up to 15°.
  • Helen of Troy cares about the environment, please recycle

Distributed by:
Felton Grimwade & Bosisto’s Pty. Ltd. 61-81 Clarinda Road (PO Box 74), Oakleigh South, Victoria 3167, Australia

Customer service:
Free call: 1800 655 841
E-mail: cservice@fgb.com.au
Website: www.fgb.com.au
Australian sponsor:

RQSolutions Pty Ltd

Suite 1A Level 2, 802 Pacific Highway, Gordon NSW 2072
Visit: www.VicksThermometers.com
Please be sure to specify the model number.
© 2021 All rights reserved.
Kaz USA, Inc., a Helen of Troy Company 400 Donald Lynch Blvd., Suite 300 Marlborough, MA 01752 Certain trademarks are used under license from The Procter & Gamble Company or its affiliates.
Made in China
Quality Requirement of Artwork and Quality
Clarification Process of Artwork Printing:
Meet Eng-QS-06&0
Helen of Troy
Creative Services
Marlborough, MA 01752 USA
+1 508 490 7000

For More Manuals by Vicks, the Latest Manuals

Leave a Reply