ABESTORM SNS100 Pint Commercial Dehumidifier Pump User Manual

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-featured

Abestorm-logo

ABESTORM SNS100 Pint Commercial Dehumidifier Pump

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-product

About Abestorm

Abestorm Crawl Space NeatyFresh Max allows for the free circulation of air on the porch and under the house. High moisture levels in the crawl spaces can lead to the decay and rot of wooden pillars that support the house, floor, joists, and beam pillars. Also, high humidity causes an increase in termite activity and the growth of fungi. Rust, which causes corrosion and leaks in metallic pipes, is also factored into the moisture level in your crawl space.

With our ventilation fan, radon gas from treated wood is expelled away. This gas and other odors can easily spread into the living room and cause discomfort. The NeatyFresh Max fan uses a humidity switch to control the fan to commence operation. The fan starts operating when the recorded humidity surpasses the selected value.

Important Notes

  • Always connect your dehumidifier using a grounded electrical connection (as required for all electrical appliances). The use of non-grounded wiring will void the warranty.
  • Your dehumidifier should only be repaired by a qualified technician.
  • Do not use the dehumidifier in standing water. If there is a chance that the dehumidifier has been flooded, unplug the unit, remove the cover, and allow it to dry completely before proceeding.
  • Do not insert objects or your fingers into the inlet or discharge.
  • Do not use water to clean the exterior of the dehumidifier. To clean the unit, unplug from the power, then use a damp cloth to wipe the exterior.
  • Please do not stand on a dehumidifier or place objects on it.
  • Do not use an extension cord or plug adapter.
  • Unless otherwise noted, all maintenance should be done with the unit powered off.

How It Works

Abestorm dehumidifiers use an integrated humidistat to monitor the conditioned space. When the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is then drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.

Installation Requirements

  • The area where the dehumidifier is located should be sealed with a vapor barrier.
  • All vents should be sealed if the unit is installed in a crawl space.
  • For proper ventilation, neither the inlet nor the discharge should be positioned against a wall.
  • The inlet needs a minimum of 6′ clearance and the discharge requires a minimum of 6′ clearance.
  • For better use of the dehumidifier, both air inlet and air outlet should be facing the open area of the space.
  • Abestorm dehumidifiers are only intended for operation when the unit is upright and level with the feet on the ground.

Key Functions

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-1

Power Key

  • Use this button to turn the dehumidifier on and off.
  • Press once to turn the machine on. You will hear one beep and the f, light will illuminate green (solid or flashing depending on mode).
  • Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a 1-minute fan delay.

Arrow Buttons

  • Use the up and down arrow buttons to set the desired humidity setpoint on the display screen. 88
  • The set point can be any number between 36%-90%. When the indoor humidity is higher than the setpoint, the unit will operate.
  • Remember that the displayed humidity levels are approximate (+/-5%).

Continuous Mode

  • To set the unit to run continuously regardless of humidity, simply use the down arrow key to set the humidity below 36%.
  • The continuous light will illuminate green and the display will show “CO”.
  • To switch back to normal humidistat operation, use the arrow keys to move the setpoint above 36%.

Manual Drain Button

  • If you need to store or move your dehumidifier, press the “Drain” button to remove water from the integral numn’s reservoir.

Remote Control Instructions

Abestorm Dehumidifiers can be controlled using an optional remote accessory. The remote connects to your dehumidifier via a 25′ CAT 5 cable, with the integrated sensor giving you multiple options for monitoring surrounding conditions.

  • Example #1- Install the dehumidifier in the laundry room and duct it into the living room. Mount the remote in the living room and use the remote sensor.
  • Example #2- Install the dehumidifier in your crawl space with the remote mounted in your garage.

NOTE: The symbols indicated below only show when the remote is powered on.

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-2

  1. On/Off (Power) Button
    Press the on/off button and the machine will start running (two beeps). Press the button again to turn the machine off.
  2. Up Button/ Down Button
    Use the up and down arrows to adjust the humidity level.
  3. Mode
    Use the mode button to switch between a dehumidifier and a ducted application.
  4. Temperature
    Press the temperature button to display the current temperature on the screen.
  5. Continuous
    Press this button to switch the unit into continuous mode. “CONT.” will appear on the display screen.
  6. Drain Pump
    Use this button if the unit will not be used for an extended period. This button will remove water from the pump reservoir.

Operating Instructions

  1. Start the machine
    • Press the power key to turn the dehumidifier on.
  2. Adjust the settings
    • Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).
  3. Stop the machine
    • Press the power button again and the dehumidifier will stop. Note that the fan will continue to operate for 1 minute after the unit has shut off.
  4. Water Drainage
    • The Abestorm Guardian SNS100 has an integrated condensate pump. During normal operation, the Guardian SNS100 will automatically drain as required.
    • If you would like to store or move your unit, press the drain button to drain water from the pump reservoir. The drain will operate for 15 seconds each time the button is pushed. It may be necessary to push the button more than once.

Unit Diagram

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-3 ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-4

Specifications

  • Capacity @ 80°F/60%RH: 100 Pints Per Day
  • Capacity @ 73°F/60%RH: 78 PPD
  • Airflow: 250 CFM
  • Operating Temp. Range: 33.8-104°F
  • Operating Relative Humidity Range: 35%-90%
  • COP: 2.7 L/kWh
  • Refrigerant: R410A
  • Amperage Usage: 6.82 Amps
  • Power Supply: 115V/60Hz/Single Phase
  • Outlet Requirement: 15 Amp, 3 prong, GFCI
  • Sound Level: 60 dBa
  • Dimensions LxWxH: 23.82×13.98×15.94 inch
  • ETL Listed: Yes

Maintenance

  • For more detailed instructions, visit www.abestorm.com
  • WARNING: Always unplug the unit before doing any maintenance.

Cleaning the Filter

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-5

  1. Unplug the unit.
  2. For PreFilter:
    • Remove the prefilter from the inlet of the machine.
    • Vacuum or wash with warm water (no soap).
  3. For MERV-10 Filter
  4. Replace as necessary- we recommend checking the filters at least 1x/year

Electrical Access

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-6

  • Unscrew the 13 screws on the side panel.
  • Remove the 2 screws on the control board cover.

Removing the Pump

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-7

  1. Remove the 9 screws on the side panel and set the panel aside.
  2. Remove the screw holding the pump in place.
  3. Undo the 3 pumps’ electrical quick connects and 1 drain quick connect.
  4. Insert a flathead screwdriver into the notch on the side of the pump. This will allow you to gently lift the pump off its reservoir (the reservoir remains attached to the unit).

Dehumidifier Storage

If the unit will be stored for an extended period, complete the following steps:

  1. Turn off the unit and allow it to dry.
  2. Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservoir.
  3. Wrap and secure the power cord.
  4. Cover the filter mesh.
  5. Store in a clean, dry space.

Ducted Applications

Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. Both the inlet/return grille and the supply grille are designed for 10″ flex ducting.

Ducting Installation Notes

  • Be sure to secure the ducting with tie wrap.
  • The maximum total length of duct run = 10′
  • Inlet and outlet duct adapters are optional accessories.

Duct Adapter InstallationABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-8

  • Screw in the 4 screws on each duct adapter.

Flex Duct InstallationABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-9

  • Slide ducting over the adapter and secure with tie wrap or clamps

Troubleshooting

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-10

Spare Parts

ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-11 ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-12 ABESTORM-SNS100-Pint-Commercial-Dehumidifier-Pump-fig-13

Limited Warranty

This limited warranty starts from the date of purchase. Abestorm Solutions Inc. warrants to the original purchaser that this Abestorm product is free from manufacturing defects in material or workmanship for the limited warranty period of:

  • Six (6) months of parts and labor. This includes the shipment charges for replacement parts or units.
  • One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced.
  • Three (3) years of parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator. Transportation cost, not included
  • Five (5) years parts on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included

This limited warranty is valid only on products purchased from the manufacturer or Abestorm authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Abestorm Solutions Inc.

will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.

To receive warranty service, the purchaser must contact Abestorm at (888)276-9833 or sales@abestorm.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of Abestorm.

Limited Warranty Exclusions

This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial, or noncommercial use of this product and shall not cover the following:

  • Damage occurs in uses for which this product was not intended.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage is caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in SPA or a room with an OUTDOOR POOL invalidates or voids the limited warranty.

Abestorm Solutions INC.
ADD: 8605 SANTA MONICA BLVD#79525 WEST
HOLLYWOOD, California, 90069 USA
E-mail: sales@abestorm.com

For More Manuals by Abestorm, visit LatestManuals

FAQs About ABESTORM SNS100 Pint Commercial Dehumidifier Pump

How does a dehumidifier sold in stores operate?

How does a commercial dehumidifier function? The majority of industrial dehumidifiers draw air in using a fan and then let it pass over cooling coils or another cold surface. As the air cools, moisture condenses and drips into a container at the unit’s base. Lastly, a fan circulates and reheats the dry air.

Do dehumidifiers sold in stores last longer?

An industrial-grade dehumidifier typically lasts nine to eleven years. However, an appliance’s lifespan can be extended even further with proper care.

How quickly does a dehumidifier function?

How Much Time Does a Dehumidifier Need to Dry Up a Room? How long it takes a dehumidifier to dry out a room depends on several factors, including its size, humidity level, and degree of water damage. For a dehumidifier to fully dry out a space, it usually takes 24 to 72 hours.

Are dehumidifiers water pumps?

When the drainage line is connected, dehumidifiers without an integrated pump rely on gravity or drainage into a bucket. Dehumidifiers that have pumps enable water to drain without relying on gravity; when needed, the water will flow upward.

When is it okay to turn off a commercial dehumidifier at night?

A: Industrial dehumidifiers are made to run continuously. It’s safe and efficient to leave them on overnight because they maintain constant moisture management while you sleep.

How long does a commercial dehumidifier last?

While dehumidifiers are designed to withstand extreme conditions, industrial and institutional dehumidifiers typically last nine to eleven years. Usually, maintaining an aging machine is more expensive than just getting a new dehumidifier.

When does a dehumidifier stop functioning due to temperature?

The unit will turn off if the outside temperature rises above 95°F or falls below 41°F.

What is the daily pint amount of dehumidifier?

“Aim for a dehumidifier rated to remove 40 or more pints of water per day if you have a large wet area that is saturated with rainwater.” You might probably get away with a unit that is rated to remove 30 pints per day or less for leaks that caused little more than a modest amount of interior dampness,” he advises.

Do dehumidifiers provide any cooling?

A dehumidifier draws moisture out of the air and then returns dried hot air that circulates throughout your space, naturally heating and cooling the air as it does so. This process of warming is most apparent in humid, moist rooms with higher relative humidity, which will feel less comfortable.

Do dehumidifiers sold in stores function?

Can damp problems be resolved with a commercial dehumidifier? By eliminating moisture from the air, commercial dehumidifiers aid in the drying out of damp areas. For example, a dehumidifier would aid in drying out the area if a building was flooded. However, damp-proofing techniques could also be required.

Leave a Reply