About Abestorm

Abestorm Crawl Space NeatyFresh Max allows for the free circulation of air on the porch and under the house. High moisture levels in the crawl spaces can lead to the decay and rot of wooden pillars that support the house, floor, joists, and beam pillars. Also, high humidity causes an increase in termite activity and the growth of fungi. Rust, which causes corrosion and leaks in metallic pipes, is also factored into the moisture level in your crawl space.

With our ventilation fan, radon gas from treated wood is expelled away. This gas and other odors can easily spread into the living room and cause discomfort. The NeatyFresh Max fan uses a humidity switch to control the fan to commence operation. The fan starts operating when the recorded humidity surpasses the selected value.

INFORMATION

The Abestorm crawlspace ventilator series is designed to circulate fresh outdoor air under the house and porch. Excessive humidity in crawl Spaces is a major cause of premature decay of support columns, joists, floors, and beam supports.

Humidity can promote fungal growth and increase termite activity. Humidity can also cause pipes to rust, corrode, and fail.

Continuous operations help release radon gas, treated wood exhaust, and other odors that may migrate to living areas. NeatyFresh 260/260S, NeatyFresh 540/540S, NeatyFresh 720/ 720S are equipped with a humidity switch. If the relative humidity rises above a selected set value, the dehumidifier will start the fan.

Suitable environment: The humidity in low buildings is between 40-60 degrees, and some environments with humidity above 80 degrees are invalid, such as in a greenhouse.

IMPORTANT: All models are equipped with factory pre-installed thermostats to prevent fan operation when outdoor temperatures fall below 35°F. When the outdoor temperature rises to near 50°F, the fan will return to normal operation.

PRECAUTIONS

WARNING!

Crawlspace ventilator fan must be installed by qualified installers by these instructions and all local codes or, in the absence of such codes, by the latest version of the International Housing Code and the International Electrical Code. Improper installation may result in dangerous situations such as fire, electric shock, or personal injury.

To significantly reduce these risks, use the device only in the manner specified by the manufacturer. If you have any questions, please contact Abestorm. Always disconnect the crawlspace ventilator before installation and maintenance.

Note:

  • For general ventilation only. Do not use to vent dangerous or explosive substances and vapors.
  • Disconnect the power supply before servicing or replacing fans.
  • Keep fingers, tools, clothing, and other foreign material away from fan blades.

REQUIRED TOOLS

  • 5/16″ Nut Driver or flathead screwdriver.
  • Drill with 5/16″ masonry bit if mounting on brick or foundation block.
  • Grounded electrical outlet within 6 feet of ventilator location.

INSTALLATION

Location: Install crawlspace ventilation in the crawl space behind the existing base ventilation hole. Vents should be installed a minimum of 3 feet from the corner of a building.

Note: Crawlspace fans must be installed in electrical control boxes and motors facing inside the crawlspace.

  1. Remove the cover of existing doors or ventilation holes around the building.
  2. Place the crawl space ventilator above the vent.
  3. If mounted on a base block or brick, mark positions at the four corners of the metal panel and drill 5/16″ holes with a masonry bit. Install wall anchors at the opening and secure the crawlspace ventilator to the wall with 4 screws.
  4. If installed on a mesh of wood aggregate, edge joists, or existing crawlspace vents, secure crawl space vents with screws, washers, and nuts at the four corners of the metal panel of the vent.

Abestorm-260CFM-Crawlspace-Ventilator-Fan-FIG-1

MOUNTING PLATE TRIM DIMENSIONS

If the mounting plate needs to be modified to fit the opening, the following decoration recommendations should be followed.

NOTE: Be careful when trimming the mounting plate to avoid damage to the power cord, and wear protective dominant to avoid caratahoa!

Abestorm-260CFM-Crawlspace-Ventilator-Fan-FIG-2 Abestorm-260CFM-Crawlspace-Ventilator-Fan-FIG-3

FREEZE PROTECTION THERMOSTATIC ACTIVATION RANGE

IMPORTANT: All models are equipped with factory pre-installed thermostats to prevent fan operation when outdoor temperatures fall below 35°F.

FAULT DESCRIPTION

  • Question: What may cause the fan to stop?
  • Answer: 1. First check whether the crawling space reaches the humidity you set or the fan shuts down due to the low outdoor temperature. If it is the above two cases, please reset your fan.
  •  Check whether your circuit is normal and whether the machine is properly connected to the circuit.
  • Question: What is the reason for the sudden noise when the fan has been in normal use?
  • Answer: 1. Check whether there is any foreign matter inside the fan, which may cause the noise caused by impacting the wheel blade.
  • 2. Check whether the mounting plate is securely assembled. Loose screws and unstable mounting plates may cause noise.

GENERAL INFORMATION

Each NeatyFresh crawlspace ventilator fan is electrically factory-tested before shipment. After unpacking, inspect the goods thoroughly for damage.

The fan should turn freely and all wires and connections should be firm. If any damage is found, immediately notify the carrier and your reseller and submit a hidden damage claim.

SPECIFICATIONS

NeatyFresh 260/260S

Abestorm-260CFM-Crawlspace-Ventilator-Fan-FIG-4

  • Capacity: 260 CFM
  • Motor: 115V AC~ 50/60Hz 0.25A
  • Thermostat: ON at 50°F / OFF at 35°F
  • Dehumidistat: -10% – 80% RH Range
  • Dimensions: 13 ⅓” × 2 ½” × 9″

NeatvFresh 540/540S

Abestorm-260CFM-Crawlspace-Ventilator-Fan-FIG-5

  • Capacity: 540 CFM
  • Motor: 115V AC~ 50/60Hz 0.51A
  • Thermostat: ON at 50°F / OFF at 35°F
  • Dehumidistat: 10% – 80% RH Range
  • Dimensions: 15″ × 2 ⅘ ” × 10 ⅕”

NeatyFresh 720/720S

Abestorm-260CFM-Crawlspace-Ventilator-Fan-FIG-6

  • Capacity: 720 CFM
  • Motors: 115V AC~ 50/60Hz 0.7A
  • Thermostat: ON at 50°F / OFF at 35°F
  • Dehumidistat: 10% – 80% RH Range
  • Dimensions: 16.5″ x 11.1″ x 4. 1″

WARRANTY

ABESTORM TWO YEARS LIMITED WARRANTY

Abestorm warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for (2) years from the date of original purchase or delivery to the original purchaser, whichever is earlier.

IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY.

Some states do not allow limitations on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries regarding warranty work to Abestorm.

IDENTIFICATION

Congratulations on purchasing an Abestorm crawlspace ventilator series For your convenience in submitting a warranty claim in the future, be sure to note the serial and the date of purchase below.

Add: 8605 SANTA MONICA BLVD#79525
WEST HOLLYWOOD, California, 90069 USA
E-mail: sales@abestorm.com
website: www.abestorm.com

FAQs About Abestorm 260CFM Crawlspace Ventilator Fan

Are fans of crawl space good or bad?

It’s crucial to remember, though, that installing a fan in your crawl area won’t resolve issues with moisture and humidity. Many vent fans let outside air into the crawl space, which frequently results in further moisture buildup and even worse issues.

Which fan works best for drying out a crawl space?

The ATMOX Internal Fan, which quietly functions and circulates air throughout the crawl area, is the most widely used. It has a capacity of 145 CFM.

Will a fan lower the crawl space’s humidity level?

Because of this, we can state with confidence that fans are not the best option for improving indoor air quality and that they will not reduce the relative humidity in your crawlspace.

In the winter, should you operate a crawl space fan?

Winterizing your HVAC system involves shutting off the vents. By doing this, the pipes inside the crawl area are kept from freezing by the dry, chilly winter air. condensation in the crawl space. Due to exposed vents and inadequate moisture control, condensation occurs in many homes constructed on crawl space foundations.

How Do Crawl Space Automatic Vents Operate?

A bi-metal coil allows the vent to open and close on its own without the need for energy. The vent fully opens to supply fresh intake air when the temperature hits 70°F, and it entirely closes to preserve energy and safeguard pipes when the temperature approaches about 40°F.

What is a crawl space vent used for?

A vented crawl space is a common feature of homes having one. A foundation vent, often known as a crawl space vent, might be compared to an upstairs window. By opening the crawl space vents, you may admit chilly air in the winter and hot, humid air in the summer into your crawl space.

Is insulation present in crawl spaces?

Insulation of a crawl space is mandated by the International Residential Building Code. The crawl space needs to be insulated if it is open or vented. If the crawl area is enclosed, insulation is required.

Can I hide vents in my crawl space?

Experts will probably advise covering your crawl space vents with plastic or aluminum covers if they find that they are the source of your problems. Tar or silicone is used to seal these lids, keeping air from getting inside or out.

Are foundation vents truly effective?

The purpose of this was to keep moisture from accumulating in your crawl space. Vents, regrettably, defy common sense. Rather than encouraging fresh airflow, they let frost and heat seep into your crawl space.

If my crawl area is vented, how can I tell?

Your home’s crawl area vents are visible on the exterior. The number of these vents in your property will depend on its size.

For More Manuals by Abestorm, Visit LatestManuals

Abestorm 260CFM Crawlspace Ventilator Fan User Manual 10 Abestorm 260CFM Crawlspace Ventilator Fan User Manual [pdf]

Leave a Reply